The measurement that matters
Measure the structural opening, not the existing door or the existing frame. The frame is what's being replaced, so its size tells you nothing about what will fit.
Take the width brick-to-brick at the top, middle and bottom of the opening and use the smallest figure. Do the same for height at the left, centre and right, measuring from the underside of the lintel down to the finished threshold.
- Use a metal tape, not a fabric one
- Measure in millimetres — every supplier works in mm
- Three readings each way, always take the smallest
- Measure the structural opening, never the old frame
- Note whether there is a step or a level threshold
The three mistakes we see most
Measuring the door slab rather than the opening. This produces a number that's always too small and a quote that's always too low.
Assuming the opening is square. On older Leicestershire terraces and anything with historic settlement it very often isn't, which is why the smallest of three readings is the safe one.
Forgetting the threshold. A level-access threshold, a stone step and a tiled internal floor all change the height available.
Why we still send a technical surveyor
A made-to-measure door has no adjustment. If the manufactured frame is 8mm too wide it cannot go in, and nobody refunds a custom product because the opening was mis-measured.
So the accountability sits with us: we measure, we order, and if it's wrong it's our problem to fix. That's the whole reason we don't take homeowner measurements for manufacture.
Send us your rough sizes for a guide price
Give us the opening measurements and the door style you like and we'll come back with a realistic figure before booking anything.